DC/DC Converter Application Note

The Under Voltage Lock Out Function (UVLO)

To provide more stable operation some DC/DC converters contain a UVLO (Under Voltage Lock Out) function. After turning on power, the UVLO function keeps the internal circuits in the standby state until the DC/DC converter input voltage (VIN) reaches the UVLO released voltage, it is to avoid malfunctioning of the product below the UVLO voltage. In case the input voltage (VIN) drops below the UVLO detect voltage during operation, the UVLO function forces the DC/DC converter into the standby state to prevent to a malfunctioning. When the input voltage (VIN) rises above the UVLO released voltage again, the UVLO released the DC/DC converter.

Downloads

You can download application notes in PDF format.

  • Voltage Regulator
    (11 pages/823KB)
  • Microcontroller Supervisory ICs
    (7 pages/579KB)
  • DC/DC Converter
    (7 pages/525KB)
 

Contact Us

Page Top